Home Products Fluorocarbon Paint Fluorocarbon Coating High Performance Fluorocarbon PVDF Topcoat – Superior UV Resistance & Color Retention for Exterior Metal
PVDF Fluorocarbon · Two-Component · 20-Year Life

Fluorocarbon Topcoat
Long-Lasting Color for Exterior Steel

A two-component, room-temperature-cured finish based on fluorocarbon resin, weatherable pigments and an isocyanate curing agent. It delivers outstanding gloss and color retention, strong adhesion, scratch resistance and self-cleaning anti-pollution performance for bridges, stations, stadiums and other landmark steel structures.

Custom color · Flat80 µm DFT · 160 µm WFTA:B = 20:450 ± 2% solids20-year life
YMS Fluorocarbon Topcoat protecting high-speed railway station steelwork
YMS Paint / JIANBANG Coatings · source factory supply MOQ 200 kg · 10 T/day capacity 7–15 day delivery worldwide 50 ± 2% solid volume · flat custom color 20-year anti-corrosion life

Technical Parameters

JF-5D Fluorocarbon Topcoat — key figures

ModelJF-5D
ColorCustom color
GlossFlat
CompositionTwo-component room-temperature-cured system based on fluorocarbon resin, weatherable pigments and isocyanate curing agent
Fluorine content≥ 20%
Density~1.30 kg/L after mixing
Mixing ratioPart A : Part B = 20 : 4 by weight
Induction30 min below 10°C; 15 min above 10°C
Volume solids(50 ± 2)%
Standard film thickness80 µm dry film thickness (about 160 µm wet film thickness)
Theoretical spreading rate4.8 m²/kg at 80 µm dry film thickness
Full cure (23 ± 2°C)7 d
Flash point31°C
Pot life6 h
Drying at 20°CTouch dry 2 h · handle dry 24 h · minimum recoat 12 h
Adhesion≥ 5 MPa
Impact resistance50 cm
Key performanceGloss and color retention, strong adhesion, good scratch resistance, easy cleaning, excellent anti-pollution resistance; resistant to heat and humidity, aging, UV, impact, abrasion, oil, solvents and chemicals
Weathering1000 h heat/humidity and 1000 h salt spray: no peeling, blistering or rust
ThinnerExclusive thinner for fluorocarbon paint
Airless sprayNozzle tip 0.017–0.023 inches · spray pressure 15–18 MPa · thinner 0–15% by weight of paint
Brush / rollerRecommended — must achieve the required thickness
Application conditionsSubstrate temperature at least 3°C above dew point; relative humidity below 80%; measure close to the substrate
Surface treatmentISO 8504 evaluation; bare steel sandblasted to Sa2.5 (ISO 8501-1:2007); power-tool grinding to at least St2 acceptable for non-immersion areas
Classic coating systemH06-1 epoxy zinc-rich primer 2 × 40 µm DFT · H53-6 epoxy mica iron oxide paint 2 × 50 µm DFT · fluorocarbon topcoat 2 × 40 µm DFT
PackagingPart A: 20 kg in a 20-litre iron bucket · Part B: 4 kg in a 5-litre iron bucket
Shelf life12 months in a shady, dry, ventilated warehouse away from fire and heat; test before use if exceeded

* Performance data are reference values; actual results depend on substrate condition, dry film thickness, ventilation, humidity and coating system. Refer to the MSDS before use. Full TDS, MSDS and test reports are available on request.

Not sure which exterior coating system fits your project? Send us the substrate, exposure environment, color requirement and target film thickness — free one-to-one system recommendation from our technical team.
WhatsApp Enquiry

Packaging & Supply

Factory-direct two-component sets from the YMS / JIANBANG plant

Coating products packed for shipment
  • 20 kg + 4 kg Component SetsPart A: 20 kg in a 20-litre iron bucket. Part B: 4 kg in a 5-litre iron bucket, mixed at 20:4 by weight for a consistent fluorocarbon finish.
  • MOQ 200 kg · Fast DispatchMinimum order 200 kg per product, with 7–15 day delivery and 10 T/day production capacity. Shipped from Shanghai, Qingdao, Guangzhou, Ningbo and other ports.
  • Custom Color & Flat FinishSupplied in custom colors with a flat finish. Our technical team matches the epoxy primer, mica intermediate and fluorocarbon topcoat to your substrate and exposure.
  • 12-Month Shelf LifeStore in a shady, dry, ventilated warehouse away from fire and heat. Test before use if the shelf life is exceeded. TDS, MSDS and test reports are available on request.
Request a Sample & Quote

Core Functions

What the JF-5D fluorocarbon finish does for exterior steel

20-Year Life

Long-Term Anti-Corrosion

When used in the recommended primer / intermediate / topcoat system, the fluorocarbon finish delivers a 20-year anti-corrosion life.

UV Resistant

Color & Gloss Retention

Fluorocarbon chemistry resists UV aging and keeps color and gloss stable on exterior steel.

Self-Cleaning

Anti-Pollution Surface

Low surface energy helps dirt and pollutants wash away, keeping facades and structures clean.

Wide Resistance

Chemical & Weather Protection

Resistant to heat and humidity, salt spray, acid, alkali, oil, solvents and industrial atmospheres.

Strong Film

Impact & Scratch Resistant

Adhesion ≥ 5 MPa, impact resistance 50 cm and good bending performance for demanding steelwork.

Easy Application

Spray, Brush or Roller

Airless spray, brush and roller are all suitable with the exclusive fluorocarbon thinner.

Applications

Where Fluorocarbon Topcoat goes on

High-Speed Rail Stations
High-Speed Rail Stations

Long-lasting exterior finish for station canopies, columns and exposed steel roofs.

Airports and Stadiums
Airports & Stadiums

Decorative and protective coating for airport and stadium facades and roof steelwork.

Steel Bridges
Steel Bridges

Weather-resistant topcoat for bridge girders, railings, towers and support steel.

Photovoltaic Arrays
Photovoltaic Arrays

UV-resistant protection for solar panels, tracker frames and mounting brackets.

Wind Turbines
Wind Turbines

Color-retentive finish for complete wind turbines — blades, nacelles and towers.

Substations
Substations

Durable finish for electrical substation frames, transformers and switchgear.

How to Use · 4-Step Application Procedure

From Sa2.5 preparation to a complete fluorocarbon coating system

1
Prepare the SurfaceAll surfaces must be clean, dry and free from contamination and evaluated per ISO 8504. Sandblast bare steel to Sa2.5 (ISO 8501-1:2007); power-tool grinding to at least St2 is acceptable for non-immersion areas. Keep the substrate at least 3°C above dew point with RH below 80%.
2
Mix the ComponentsMix Part A evenly with a power mixer, then slowly add Part B at 20:4 by weight. Allow 30 min induction below 10°C or 15 min above 10°C. Use the exclusive thinner for fluorocarbon paint; pot life is about 6 h.
3
Apply the TopcoatAirless spray with a 0.017–0.023 in tip at 15–18 MPa, thinner 0–15% by paint weight. Brush and roller are also recommended where required thickness can be achieved. Target 80 µm DFT (about 160 µm WFT), or 2 × 40 µm in the classic system.
4
Cure & InspectAt 10 / 20 / 30°C: touch dry 5 h / 2 h / 1 h, handle dry 24 h / 24 h / 12 h, minimum recoat 24 h / 12 h / 6 h. Full cure is 7 d at 23 ± 2°C. Ensure no chalking or contamination before recoating. Ventilate and wear PPE as directed by the MSDS.

Note: surface preparation follows ISO 8504 / ISO 8501-1 and the YMS / JIANBANG datasheet. This product is flammable — keep away from flame, prohibit smoking, ventilate the work area and wear PPE as directed by the MSDS. Dispose of used barrels responsibly.

See It In Action

Application and quality-control moments on real project sites

Brush application of fluorocarbon topcoat on a clean steel framework

The two-component fluorocarbon topcoat is brushed onto prepared steel to build the specified 80 µm dry film.

Dry film thickness inspection on a smooth light-gray coated steel panel

Coating thickness is checked on real panels before the structure is exposed to outdoor service.

Site inspection of a completed fluorocarbon-coated steel structure

Finished steelwork is inspected for uniform film build, color consistency and system continuity.

Why Choose YMS Paint / JIANBANG Coatings

Protective coating systems with documents, capacity and export experience

26 YearsSource factory for industrial protective coatings with in-house R&D and production.
YMS / JIANBANGTwo established coating brands under one supply chain for architectural and industrial finishes.
20-Year LifeFluorocarbon system engineered for long-term color retention and anti-corrosion protection.
Full DocumentsTDS, MSDS, test reports and certificates available on request.
Free MatchingFree sample testing against your stone sample, color scheme and substrate before bulk orders.
System SupportFree matching of epoxy primer, mica intermediate and fluorocarbon topcoat to your project.

One Anticorrosion Platform, Four System Layers

Build the full primer → intermediate → finish stack

Primer

H06-1 Epoxy Zinc-Rich Primer

Cathodic zinc-rich primer at 2 × 40 µm DFT beneath the mica intermediate.

Intermediate

H53-6 Epoxy Mica Iron Oxide Paint

Barrier midcoat at 2 × 50 µm DFT for the complete exterior system.

Topcoat

JF-5D Fluorocarbon Topcoat

This product — flat custom-color finish at 2 × 40 µm DFT.

Alternative

Polysiloxane Finish

High-gloss alternative with 15–20 year color and gloss retention.

Frequently Asked Questions

What is Fluorocarbon Topcoat?

JF-5D is a two-component, room-temperature-cured topcoat based on fluorocarbon resin, weatherable pigments and an isocyanate curing agent. It offers excellent gloss and color retention, strong adhesion, good scratch resistance, easy cleaning and outstanding anti-pollution performance.

Where is it used?

It is used on high-speed railway stations, airports, stadiums, steel bridges, photovoltaic arrays, complete wind turbines, substations, chemical plants, offshore platforms and other exterior steel requiring long-term appearance retention.

What film thickness and coverage should I expect?

Standard dry film thickness is 80 µm (about 160 µm wet film), with a theoretical spreading rate of 4.8 m²/kg at 80 µm DFT. The classic system applies the fluorocarbon topcoat at 2 × 40 µm DFT.

How is it mixed and applied?

Mix Part A with a power mixer and slowly add Part B at 20:4 by weight; induction is 30 min below 10°C or 15 min above 10°C. Use the exclusive thinner. Airless spray with a 0.017–0.023 in tip at 15–18 MPa and 0–15% thinner. Brush and roller are recommended where required thickness can be achieved.

What are the drying and recoating times?

At 10 / 20 / 30°C: touch dry 5 h / 2 h / 1 h, handle dry 24 h / 24 h / 12 h and minimum recoat 24 h / 12 h / 6 h. Full cure is 7 d at 23 ± 2°C. Ensure no chalking or contamination before recoating.

What surface preparation is required?

All surfaces must be clean, dry and free from contamination and evaluated per ISO 8504. Sandblast bare steel to Sa2.5 (ISO 8501-1:2007); power-tool grinding to at least St2 is acceptable for non-immersion areas. Keep the substrate at least 3°C above dew point with RH below 80%.

What is the classic coating system?

H06-1 epoxy zinc-rich primer 2 × 40 µm DFT, H53-6 epoxy mica iron oxide paint 2 × 50 µm DFT and fluorocarbon topcoat 2 × 40 µm DFT. Contact our team for a system matched to your substrate and exposure.

How is it packed and how long does it last?

Part A: 20 kg in a 20-litre iron bucket; Part B: 4 kg in a 5-litre iron bucket. Shelf life is 12 months in a shady, dry, ventilated warehouse away from fire and heat; test before use if exceeded. MOQ is 200 kg with 7–15 day delivery.

Get a Sample & a Fluorocarbon System for Your Project

Tell us the substrate, exposure environment, color requirement and target film thickness — our engineers reply within 24 hours with a matched system, coverage estimate and quotation.

Or reach us directly: WhatsApp +86-18015818726 · ymsrecord@jsbj88.com · reply within 24 hours.