Home Products Polyurethane Paint Polyurethane Coating High-Performance Polyurethane Mica Iron Oxide Intermediate Coat
Polyurethane Coating · Mica Iron Oxide · Intermediate Paint

Polyurethane Mica Iron Oxide Intermediate Paint
High-Build Shield for Steel Structures

A two-component intermediate paint composed of hydroxyl epoxy resin containing carboxyl group, anti-rust pigments, lamellar mica iron oxide, fillers, auxiliaries and PAPI polyisocyanate curing agent. The plate-like pigment builds a tortuous barrier for thick-film shielding, rust resistance, fast drying and oil resistance — with excellent intercoat adhesion between primer and finish.

Gray / reddish-brown100 µm DFT · 180 µm WFTA:B = 20:4Touch dry 1–4 h20 kg + 4 kg set
YMS Polyurethane Mica Iron Oxide Intermediate Paint protecting large steel structures
YMS Paint / JIANBANG Coatings · source factory supply MOQ 200 kg · 10 T/day capacity 7–15 day delivery worldwide 55 ± 2% solid volume · high build 12-month shelf life

Technical Parameters

Polyurethane Mica Iron Oxide Intermediate Paint — key figures

ColorGray, reddish-brown
GlossFlat / glossy (semi-gloss grade available on request)
CompositionTwo-component intermediate paint: hydroxyl epoxy resin containing carboxyl group, anti-rust pigments, lamellar mica iron oxide, fillers, auxiliaries and PAPI polyisocyanate curing agent
Mixing ratioPart A : Part B = 20 : 4 by weight
Density~1.55 kg/L after mixing
Solid volume(55 ± 2)%
Standard film thickness100 µm dry film thickness (about 180 µm wet film thickness)
Theoretical spreading rate3.55 m²/kg at 100 µm DFT (4.2 m²/kg at 80 µm DFT on some datasheets)
HardnessPolyurethane curing-agent system
Flash pointPart A: 32°C · Part B: 27°C
Drying schedule (40 µm)To touch: 4 h @10°C / 2 h @20°C / 1 h @30°C · To handle: 24 h / 12 h / 6 h · Min. recoat: 16 h / 8 h / 4 h · Pot life: 4 h / 2 h / 1 h
MixingPower-mix Part A evenly, then add Part B and stir until fully homogeneous
ThinnerPolyurethane thinner
Airless sprayNozzle tip 0.017–0.023 inches · spray pressure 15–18 MPa · thinner 5–15% by weight of paint
Brush / rollerRecommended for small areas only — must achieve the required film thickness
Application conditionsSubstrate temperature at least 3°C above dew point; relative humidity below 85%; measure close to the substrate
Surface treatmentISO 8504 evaluation; bare steel sandblasted to Sa2.5 (ISO 8501-1:2007); power-tool grinding at least St2 outside immersion service; shop primer clean, dry and approved
Classic coating systemPolyurethane primer 2 × 40 µm DFT · Mica iron oxide intermediate 2 × 50 µm DFT · Polyurethane finish 2 × 40 µm DFT
PackagingPart A: 20 kg in a 20-litre iron bucket · Part B: 4 kg in a 5-litre iron bucket
Shelf life12 months in a shady, dry, ventilated warehouse; test before use if exceeded
CertificatesCE, ISO 9001, ISO 14001, OHSAS 18001, RoHS, SASO, SGS and SRC available on request

* Drying, recoat and pot-life data are reference values; actual performance depends on substrate temperature, dry film thickness and ventilation. Refer to the MSDS before use. Full TDS, MSDS and test reports are available on request.

Not sure which anticorrosion system fits your structure? Send us the substrate, exposure environment, target film thickness and finish — free one-to-one system recommendation from our technical team.
WhatsApp Enquiry

Packaging & Supply

Factory-direct two-component sets from the YMS / JIANBANG plant

Coating products packed for shipment
  • 20 kg + 4 kg Component SetsPart A: 20 kg in a 20-litre iron bucket. Part B: 4 kg in a 5-litre iron bucket. Supplied at a 20:4 weight mixing ratio for consistent batch-to-batch build.
  • MOQ 200 kg · Fast DispatchMinimum order 200 kg per product, with 7–15 day delivery and 10 T/day production capacity. Shipped from Shanghai, Qingdao, Guangzhou, Ningbo and other ports.
  • System & Color MatchingGray and reddish-brown standard, flat or glossy. Our technical team matches primer, intermediate and finish to your steel structure and exposure environment.
  • 12-Month Shelf LifeStore in a shady, dry, ventilated warehouse. Test before use if the shelf life is exceeded. TDS, MSDS, CE/RoHS/ISO documents and test reports ship with every order.
Request a Sample & Quote

Core Functions

What this high-build intermediate layer does for the coating system

Thick Film Build

100 µm DFT in One Pass

A high-solid (55 ± 2%) intermediate coat lays down about 100 µm dry film — 180 µm wet — so the classic system reaches its build with 2 × 50 µm intermediate coats.

Lamellar Barrier

Mica Iron Oxide Shields Steel

Plate-like mica iron oxide flakes overlap into a tortuous path that slows moisture and oxygen reaching the steel surface.

Fast Drying

Recoat in 4–16 Hours

At 40 µm DFT: touch dry in 1–4 h, handle dry in 6–24 h and ready for recoat in 4–16 h across 10–30°C.

Oil Resistance

Built for Industrial Environments

The cured polyurethane network resists oil and common industrial media, making it a dependable middle layer in demanding service.

Intercoat Adhesion

The Bridge Between Primer & Finish

Engineered as the system layer: excellent contact and adhesion with compatible polyurethane primers and topcoats.

Proven Substrates

From Cranes to Wind Towers

Specified for port cranes, bridges, transmission towers, workshops, guardrails, wind turbine towers, canopies and storage racks.

Applications

Where Polyurethane Mica Iron Oxide Intermediate Paint goes on

Port Cranes and Terminals
Port Cranes & Terminals

Thick-film mica iron oxide shielding on harbor gantry cranes and terminal steelwork exposed to salt-laden atmospheres.

Steel Bridges
Steel Bridges

Girders and cross beams stay protected through traffic vibration, temperature cycles and year-round weather.

Wind Turbine Towers
Wind Turbine Towers

Reddish-brown intermediate build on tall steel towers, paired with a weather-resistant polyurethane finish.

Transmission and Communication Towers
Transmission & Communication Towers

Lattice steel structures gain a durable barrier layer before the topcoat goes on.

Industrial Workshops and Storage Racks
Industrial Workshops & Storage Racks

Columns, beams and racking protected against corrosion and daily handling wear inside busy facilities.

Guardrails and Outdoor Canopies
Guardrails & Outdoor Canopies

Roadside steel and canopy frameworks insulated from moisture with a high-build intermediate coat.

How to Use · 4-Step Application Procedure

From Sa2.5 steel preparation to a complete PU coating system

1
Prepare the SteelAll surfaces must be clean and dry and evaluated per ISO 8504. Sandblast bare steel to Sa2.5 (ISO 8501-1:2007); power-tool grinding to at least St2 is acceptable outside immersion service. Shop primer must be clean, dry and approved, and existing coatings must be compatible.
2
Check & MixKeep the substrate at least 3°C above dew point and RH below 85%. Power-mix Part A evenly, add Part B at 20:4 by weight and stir until homogeneous. Use polyurethane thinner; observe pot life of 4 h / 2 h / 1 h at 10 / 20 / 30°C.
3
Spray the Build CoatAirless spray at 0.017–0.023 in tip and 15–18 MPa, thinner 5–15% by paint weight. Target 100 µm DFT (about 180 µm WFT), or 2 × 50 µm DFT in the classic system. Brush and roller are for small areas only.
4
Recoat & FinishRecoat after 16 h / 8 h / 4 h depending on substrate temperature, once the surface is free of chalking and contamination. Complete with polyurethane finish at 2 × 40 µm DFT. Ventilate the workspace, keep away from flame and wear PPE as directed by the MSDS.

Note: surface preparation follows ISO 8504 / ISO 8501-1 and the YMS / JIANBANG datasheet. This product is flammable — keep away from flame, prohibit smoking, ventilate the work area and wear PPE. Dispose of used barrels responsibly.

See It In Action

Application and quality-control moments on real facade projects

Spray application of polyurethane mica iron oxide intermediate paint on a steel facade frame

On-site spray application builds the specified 100 µm dry film on prepared steel facade members.

Dry film thickness inspection on a coated steel facade panel

Coating thickness is checked on real facade panels before the polyurethane finish is applied.

Site inspection of a completed coated steel facade

Finished facade steelwork is inspected for uniform build, surface quality and system continuity.

Why Choose YMS Paint / JIANBANG Coatings

Protective coating systems with documents, capacity and export experience

26 YearsSource factory for industrial protective coatings with in-house R&D and production.
YMS / JIANBANGTwo established coating brands under one supply chain for anticorrosion systems.
High Build55 ± 2% solids and ~100 µm DFT per pass reduce the number of application cycles.
Full DocumentsTDS, MSDS, test reports, CE/RoHS/ISO and OHSAS certificates available on request.
Free MatchingFree sample testing against your stone sample, color scheme and substrate before bulk orders.
System SupportFree matching of primer, intermediate and finish to your substrate, environment and target film thickness.

One Anticorrosion Platform, Four System Layers

Build the full primer → intermediate → finish stack

Polyurethane System

Polyurethane Mica Iron Oxide Intermediate Paint

This product — lamellar high-build bridge coat, 100 µm DFT, A:B 20:4, fast drying.

Epoxy System

Epoxy Micaceous Iron Oxide Intermediate

High-build epoxy alternative for severe corrosion environments where maximum barrier performance is required.

Primer

Polyurethane Primer

Red-oxide PU primer applied at 2 × 40 µm DFT as the base of the classic three-coat system.

Topcoat

Acrylic Polyurethane Topcoat

Weather-resistant decorative finish applied at 2 × 40 µm DFT for color and gloss retention.

Frequently Asked Questions

What is Polyurethane Mica Iron Oxide Intermediate Paint?

A two-component intermediate paint composed of hydroxyl epoxy resin containing carboxyl group, anti-rust pigments, lamellar mica iron oxide, fillers, auxiliaries and PAPI polyisocyanate curing agent. It builds a thick, shielding layer between primer and finish.

Why use mica iron oxide in the middle coat?

The plate-like mica iron oxide flakes overlap to create a tortuous barrier that slows moisture and oxygen penetration. Combined with high solids and thick-film build, this delivers strong shielding and rust resistance.

What film thickness and coverage should I expect?

Standard dry film thickness is 100 µm (about 180 µm wet), with a theoretical spreading rate of 3.55 m²/kg at 100 µm DFT. Some datasheets quote 4.2 m²/kg at 80 µm DFT. The classic system uses 2 × 50 µm for the intermediate coat.

How is the coating mixed and applied?

Power-mix Part A, then add Part B at 20:4 by weight and mix thoroughly. Use polyurethane thinner at 5–15% for airless spray with a 0.017–0.023 in tip at 15–18 MPa. Brush and roller are recommended for small areas only.

What are the drying and recoat times?

At 40 µm DFT: touch dry 4 h / 2 h / 1 h, handle dry 24 h / 12 h / 6 h, minimum recoat 16 h / 8 h / 4 h, pot life 4 h / 2 h / 1 h at substrate temperatures of 10 / 20 / 30°C.

What surface preparation is required?

Clean and dry surfaces per ISO 8504. Bare steel should be blasted to Sa2.5 (ISO 8501-1:2007); power-tool cleaning to at least St2 is acceptable outside immersion service. Keep the substrate 3°C above dew point and RH below 85%.

What is the classic coating system?

Polyurethane primer 2 × 40 µm DFT, polyurethane mica iron oxide intermediate 2 × 50 µm DFT, and polyurethane finish 2 × 40 µm DFT. Contact our team for a system matched to your structure.

How is it packed and how long does it last?

Part A: 20 kg in a 20-litre iron bucket; Part B: 4 kg in a 5-litre iron bucket. Shelf life is 12 months in shady, dry, ventilated storage; test before use if exceeded. MOQ is 200 kg with 7–15 day delivery.

Get a Sample & an Anticorrosion System for Your Steel Structure

Tell us the substrate, exposure environment, target film thickness and topcoat — our engineers reply within 24 hours with a matched system, coverage estimate and quotation.

Or reach us directly: WhatsApp +86-18015818726 · ymsrecord@jsbj88.com · reply within 24 hours.

WhatsApp Us · +86-18015818726 Email: ymsrecord@jsbj88.com
Apply Our Best Quotation
Apply Our Best Quotation

Minimum Order Quantity (MOQ): 200 KG or 200 m² per product

© COPYRIGHT 2024 CHANGZHOU YMS NEW MATERIALS TECHNOLOGY CO., LTD. ALL RIGHTS RESERVED.