YMS COATINGS
Gray
Glossy
~1.25Kg/L(after mixing)
27℃
(48±2 )%
Use the power mixer to mix the main paint evenly, and then as you stir it, you add the hardener until you get to mix well.
Part A: Part B= 30:3 (by weight)
5.5m²/Kg (80um dry film thickness)
Availability: | |
---|---|
Two Component Anti-corrosive Paint
Two Component Anti-corrosive Paint is a long lasting anti-corrosive product composed of modified synthetic resin, film-forming assistant, composite zinc powder, and other materials through scientific and reasonable adjustment of formula.It has the following resistance characteristics:
|
|
|
|
|
|
Two Component Anti-corrosive Paint Video
Two Component Anti-corrosive Paint
Basic Technical Datasheet
Color | Gray |
Gloss | Glossy |
Density | ~1.25Kg/L (after mixing) |
Solid Volume | (48±2 )% |
Standard Film thickness | 80um dry film thickness (about 165um wet film thickness) |
Theoretical spreading rate | 5.5m²/Kg (80um dry film thickness) |
Full Cure | (23±2℃)24h |
Flash Point | 27℃ |
![]() | Two Component Anti-corrosive Paint Product PackagingPackaging: part A:30kg in a 20-liter iron bucket. part B:3kg in a 4-liter iron bucket. Shelf Life: 12 months If exceeding shelf life, the products shall be tested before using. |
![]() | ![]() | ![]() | ![]() |
Sluice gate | Bridge | substation | power plant |
![]() | ![]() | ![]() | ![]() |
steel structure | marine engineering | water transmission pipeline | chimney |
Product | Thickness | |
Paint: | Anti-corrosive Paint | 2*40 um (dry film thickness) |
Finish: | Acrylic Polyurethane Finish | 2*40 um (dry film thickness) |
![]() | ![]() | ![]() |
![]() | ![]() | ![]() |
Substrate Treatment:
All surface to be coated shall be clean and dry. The surface shall be evaluated and treated according to ISO8504 standard.
For bare steel, it shall be sandblasted to reach Sa2.5(iso8501-1:2007) standard. Depending on the environment of the non-immersed part, grinding with power tools is acceptable but shall at least reach St2(iso8501-1:2007) standard.
For shop primed steel, the shop primer shall be clean, dry and approved.
For surface painted coatings, this product can apply only to clean, dry and good compatible primer.
Instructions for Use:
Mixing:
Use the power mixer to mix the main paint evenly, and then as you stir it, you add the hardener until you to mix the paint well.
Mixing Ratio
Part A: Part B= 30:3(by weight)
Thinner:
Exclusive thinner
Airless spray:
Nozzle tip: 0.017~0.023 inches
Spray pressure: 15~18Mpa
Thinner ratio: 0~15% (by weight of paint)
Brush, Roller:
Recommended for small areas only. Must achieve required thickness
![]() | |||
![]() | ![]() | ![]() | ![]() |
![]() | ![]() | ![]() |
![]() | ![]() | ![]() |
Two Component Anti-corrosive Paint
Two Component Anti-corrosive Paint is a long lasting anti-corrosive product composed of modified synthetic resin, film-forming assistant, composite zinc powder, and other materials through scientific and reasonable adjustment of formula.It has the following resistance characteristics:
|
|
|
|
|
|
Two Component Anti-corrosive Paint Video
Two Component Anti-corrosive Paint
Basic Technical Datasheet
Color | Gray |
Gloss | Glossy |
Density | ~1.25Kg/L (after mixing) |
Solid Volume | (48±2 )% |
Standard Film thickness | 80um dry film thickness (about 165um wet film thickness) |
Theoretical spreading rate | 5.5m²/Kg (80um dry film thickness) |
Full Cure | (23±2℃)24h |
Flash Point | 27℃ |
![]() | Two Component Anti-corrosive Paint Product PackagingPackaging: part A:30kg in a 20-liter iron bucket. part B:3kg in a 4-liter iron bucket. Shelf Life: 12 months If exceeding shelf life, the products shall be tested before using. |
![]() | ![]() | ![]() | ![]() |
Sluice gate | Bridge | substation | power plant |
![]() | ![]() | ![]() | ![]() |
steel structure | marine engineering | water transmission pipeline | chimney |
Product | Thickness | |
Paint: | Anti-corrosive Paint | 2*40 um (dry film thickness) |
Finish: | Acrylic Polyurethane Finish | 2*40 um (dry film thickness) |
![]() | ![]() | ![]() |
![]() | ![]() | ![]() |
Substrate Treatment:
All surface to be coated shall be clean and dry. The surface shall be evaluated and treated according to ISO8504 standard.
For bare steel, it shall be sandblasted to reach Sa2.5(iso8501-1:2007) standard. Depending on the environment of the non-immersed part, grinding with power tools is acceptable but shall at least reach St2(iso8501-1:2007) standard.
For shop primed steel, the shop primer shall be clean, dry and approved.
For surface painted coatings, this product can apply only to clean, dry and good compatible primer.
Instructions for Use:
Mixing:
Use the power mixer to mix the main paint evenly, and then as you stir it, you add the hardener until you to mix the paint well.
Mixing Ratio
Part A: Part B= 30:3(by weight)
Thinner:
Exclusive thinner
Airless spray:
Nozzle tip: 0.017~0.023 inches
Spray pressure: 15~18Mpa
Thinner ratio: 0~15% (by weight of paint)
Brush, Roller:
Recommended for small areas only. Must achieve required thickness
![]() | |||
![]() | ![]() | ![]() | ![]() |
![]() | ![]() | ![]() |
![]() | ![]() | ![]() |