Home Anti-corrosion Primer Hydrofluoric Acid‑Resistant Anticorrosive Coating
JB-406 · Special Acid-Resistant Anticorrosive Coating

JB-406 Hydrofluoric Acid-Resistant Anticorrosive Coating
Inert to HF, Barrier Against Mixed Acid

JB-406 is a two-component, (98±2)% volume-solid anticorrosive coating built on modified phenol-fluoride resin and polyhydroxy ester with a special hydrocarbon wax additive system and isocyanate curing agent. Curing forms an interpenetrating polymer network (IPN), while the completely silicon-free filler package — silicon carbide, graphite and barite instead of the glass flake and silica that HF dissolves — keeps the film chemically inert to hydrofluoric acid. It withstands 50% HF + 50% HNO₃ mixed acid for long-term service on HF tanks, nitric acid towers, pickling lines, fluorochemical plants and coastal steel structures.

50% HF + 50% HNO₃Silicon-free inert fillersIPN dense barrier(98±2)% solidsGrey · matt or gloss
JB-406 hydrofluoric acid-resistant anticorrosive coating — YMS Paint two-component kit
26-year source factory · local plant in Indonesia (98±2)% solid volume · near-zero solvent loss 50% HF + 50% HNO₃ mixed-acid resistant 4 m²/kg coverage at 200 μm DFT Exported to 87 countries

Technical Parameters

JB-406 product data sheet (TDS) — key figures

ColorGrey
GlossMatt or bright
Density~1.47 kg/L (mixed)
Curing agentSpecial curing agent
Volume solid(98±2)%
Standard film thickness200 μm DFT (~205 μm wet film)
Theoretical coverage4 m²/kg (at 200 μm dry film)
Flash point57°C
Mixing ratioBase : curing agent = 2 : 1 by weight
Pot life (after mixing)20 min (at 10 / 20 / 30°C)
Drying (200 μm) at 10°CSurface dry 48 h · hard dry 96 h · min recoat 2 h
Drying (200 μm) at 20°CSurface dry 24 h · hard dry 72 h · min recoat 1 h
Drying (200 μm) at 30°CSurface dry 12 h · hard dry 48 h · min recoat 30 min
Application methodBatch / touch-up and roller — pre-coat and small areas at the specified DFT
ThinnerSpecial thinner
Surface preparationISO8504 — bare steel blast-cleaned to Sa2.5 (ISO8501-1:2007); power-tool St2 min. for non-immersed areas; stainless steel roughened with non-metallic abrasive; galvanized steel clean, dry and roughened
Application conditionsSubstrate temperature ≥3°C above dew point; relative humidity <85%
Full cure (23±2°C)7 days — allow 7–15 days before service for best performance

* Data from the official JB-406 TDS. Full TDS, MSDS and test reports are available on request.

Not sure which coating fits your corrosion media? Send us the media type, concentration, temperature and equipment type — free one-to-one system recommendation from our coating engineers.
WhatsApp Enquiry

Packaging & Supply

Factory-direct kits, packed and shipped from the JIANBANG plant

JIANBANG factory, packed paint kits and container loading for export
  • Two-Component KitPart A 20 L / 20 kg drum + Part B 20 L / 10 kg drum. Mix 2 : 1 by weight right before application — the reaction completes in 10–15 minutes with strong heat release, so mix only what can be applied within the 20-minute pot life.
  • (98±2)% Solids, No WasteNear-solvent-free formulation cures into the finished film — predictable coverage of 4 m²/kg at a 200 μm dry film thickness.
  • Custom PackingStandard kit packing; other drum sizes and packing can be customized to your destination market and label requirements.
  • Shelf Life & Storage12 months in cool, dry, ventilated storage away from heat sources; re-inspection is required after the shelf life before use.
Request a Sample & Quote

Core Functions

Why JB-406 survives where ordinary acid-proof coatings dissolve

HF Inertness

Silicon-Free Filler Package

HF dissolves glass, quartz and silica. JB-406 replaces glass flake and silica fillers with silicon carbide, graphite and barite — the film itself never reacts with hydrofluoric acid.

Chemical

Mixed-Acid Resistance

Long-term resistance to high-concentration hydrofluoric acid at ambient temperature and to HF + nitric acid mixed systems (50% HF + 50% HNO₃), verified on fluorine-chemical service.

Barrier

Dense IPN Network

High crosslink density with extremely low porosity blocks fluoride ions, water and oxygen — a sealed barrier that keeps corrosive media away from the substrate.

Adhesion

Strong Interface Bond

Polar functional groups chemically bond and anchor to steel and concrete — no blistering or underfilm corrosion, and local damage does not spread.

Durability

Mechanical Toughness

Hard, wear-resistant film withstands tank entry/exit and pipeline scour; the dispersed wax crystals form a hydrophobic shield with micro-crack self-repair.

Cure

Fast Ambient Cure

Two-component ambient cure with 20 min pot life and recoat windows from 30 min (30°C) — full protection reached after 7–15 days curing.

Film

200 μm Long-Acting Film

4 m²/kg at 200 μm DFT for economical protection. Outdoor exposure may chalk the surface layer only — appearance only, no loss of anticorrosive performance.

Applications

Where JB-406 earns its place against fluoride-bearing media

HF & Chemical Storage Tanks protected by JB-406 hydrofluoric acid-resistant coating
HF & Chemical Storage Tanks

Fluorine-chemical storage tanks and reactors handling hydrofluoric acid and fluoride-bearing media.

Nitric Acid Absorption Towers protected by JB-406 hydrofluoric acid-resistant coating
Nitric Acid Absorption Towers

Nitric acid towers, cooling and absorption structures exposed to HF / HNO₃ environments.

Acid Pickling Workshops protected by JB-406 hydrofluoric acid-resistant coating
Acid Pickling Workshops

Pickling tank linings and workshop bunds in steel pickling and surface-treatment lines.

Fluorochemical Plant Piping protected by JB-406 hydrofluoric acid-resistant coating
Fluorochemical Plant Piping

Pipe racks, ducts and steel frameworks inside fluorochemical production plants.

Effluent & Waste Liquid Pools protected by JB-406 hydrofluoric acid-resistant coating
Effluent & Waste Liquid Pools

High-corrosion waste liquid basins and neutralization pools handling mixed-acid effluent.

Coastal & Marine Structures protected by JB-406 hydrofluoric acid-resistant coating
Coastal & Marine Structures

Offshore platform splash zones and coastal plant steelwork — the TDS recommended use.

How to Use · 4-Step Operating Procedure

From surface preparation to a fully cured acid barrier

1
Prepare & BlastImmersed steel: blast to Sa2.5 (ISO8501-1:2007); non-immersed areas: power-tool St2 min.; stainless/galvanized: roughen. Substrate ≥3°C above dew point, RH <85%.
2
Mix A + B = 2 : 1Stir the base, then add the curing agent gradually while mixing. The reaction completes in 10–15 min with strong heat release — use within the 20-minute pot life.
3
Apply 200 μmApply with special thinner by batch/touch-up or roller (~205 μm wet film). Recoat after 30 min–2 h depending on temperature; surface must be dry and dust-free.
4
Cure 7–15 DaysFull cure at (23±2)°C in 7 days; allow 7–15 days in service before chemical exposure for best performance.

Safety: read the container notice, use with good ventilation, avoid mist inhalation and skin contact — flush with soap and water after skin contact and with water after eye contact, then seek medical advice. Dispose of empty drums responsibly.

See It In Action

Field environments where JB-406 protects steel and concrete

Nitric acid towers and cooling tower structures protected by JB-406

Field-proven on acid towers and flue-gas desulfurization environments.

Steel truss structures and plant frameworks coated with JB-406

Protecting steel trusses, pipe racks and plant frameworks.

Third-party test report and certification of JB-406

Third-party test reports and certificates for every batch.

Why Choose YMS Paint / JIANBANG Coatings

More than a paint supplier — your anticorrosion system partner

26 YearsSource factory specialized in industrial anticorrosion coatings.
87 CountriesExported worldwide with a local plant and service in Indonesia.
Specialty LineJB-98 / JB-406 / JB-800 / JB-8866 cover acids, HF, solvents and 1200°C heat.
Full DocumentsTDS, MSDS, test reports and certificates supplied with every order.
Free MatchingCondition survey and sample testing before bulk orders.
Custom PackingDrum sizes, labels and packing arranged per destination market.

One Specialty Platform, Four Hardcore Coatings

Match the coating to the media — full temperature and chemistry range

JB-98

Heavy-Duty Acid-Resistant Coating

100% solids, zero solvent — resists 98% sulfuric acid for 720 h without blistering. For acid tanks, reactors and pipelines.

JB-406

Hydrofluoric Acid-Resistant Coating

This product — silicon-free inert fillers and dense IPN network for 50% HF + 50% HNO₃ mixed acid service.

JB-800

Ultra-High-Temperature Coating

Withstands up to 1200°C; no peeling after 800°C water quench. For high-temp furnaces and exhaust pipes.

JB-8866

Extreme Chemical-Resistant Coating

Resists strong solvents and saturated NaOH. For solvent tanks, alkali pools and reactors.

Frequently Asked Questions

What is JB-406 Hydrofluoric Acid-Resistant Anticorrosive Coating?

A two-component, (98±2)% volume-solid special acid-resistant coating based on modified phenol-fluoride resin, polyhydroxy ester and isocyanate curing agent. It is designed for hydrofluoric acid and fluoride-bearing mixed-acid media, applied at a 200 μm dry film thickness by roller or batch application.

Why must the fillers be silicon-free?

HF dissolves glass, quartz and almost all silicon-containing materials. Ordinary glass-flake or silica-filled coatings are rapidly eaten away. JB-406 uses silicon carbide, graphite and barite — completely inert to fluoride — so the film itself never reacts with HF and no penetration holes are left behind.

Which acids does it resist?

Long-term resistance to high-concentration hydrofluoric acid and HF + nitric acid mixed systems (50% HF + 50% HNO₃) at ambient temperature, with the dense IPN network blocking fluoride-ion, water and oxygen penetration to the substrate.

How is it mixed and applied?

Mix base and curing agent at 2 : 1 by weight — the reaction completes in 10–15 minutes with strong heat release, so apply within the 20-minute pot life. Apply by roller or batch/touch-up at ~205 μm wet film (200 μm dry). Recoat after 30 min–2 h depending on temperature.

What surface preparation is required?

Surfaces must be clean, dry and evaluated per ISO8504. Bare steel: blast to Sa2.5 (ISO8501-1:2007); non-immersed areas may use power tools to at least St2. Stainless steel: roughen with non-metallic abrasive; galvanized steel: clean, dry and roughened. Substrate ≥3°C above dew point, RH <85%.

How is it packed and how long does it last?

Part A: 20 L / 20 kg drum; Part B: 20 L / 10 kg drum; other packing can be customized. Shelf life is 12 months in cool, dry, ventilated storage away from heat; re-inspect after expiry before use.

The film chalks outdoors — is that a problem?

No. Chalking and fading occur only in the surface layer on atmospheric exposure and have no adverse effect on the anticorrosive performance. Clean and recoat if the appearance needs refreshing.

Get a Sample & a Corrosion-Protection Specification for Your Plant

Tell us the media, concentration, temperature and equipment type — our engineers reply within 24 hours with a matched system, coverage estimate and quotation.

Or reach us directly: WhatsApp +86-17312895118 · inquiry@jsbj88.com · reply within 24 hours.

WhatsApp Us · +86-17312895118 Email: inquiry@jsbj88.com
Apply Our Best Quotation
Apply Our Best Quotation

Minimum Order Quantity (MOQ): 200 KG or 200 m² per product

© COPYRIGHT 2024 CHANGZHOU YMS NEW MATERIALS TECHNOLOGY CO., LTD. ALL RIGHTS RESERVED.